SPACIUM electrical box
Recommended retail price 2024 starting from :
464 €
Our Price starting from :
464 € Including VAT
Ref. Abatik 007950
Ref. Provider SPAF1PAD
SPACIUM electrical box with trip switch 4-6.3 single-phase Filtration + 1 300 W projector + 1 slave connection
Ref. Provider SPAF1PAD
SPACIUM electrical box with trip switch 4-6.3 single-phase Filtration + 1 300 W projector + 1 slave connection
Electrical box with timeclock
Wall anchoring
Sold with or without trip switch
Wall anchoring
Sold with or without trip switch
In stock
The electrical box allows you to command and protect your filtration pump, power and protect your pool projectors. Depending on the chosen model, you can also command and protect other pool equipment, such as booster pumps, electrolysers, dosing pumps etc.
In respect of electrical norms C15-100 the power supply of an electrical box for filtration purposes should be fitted with a 30mA differential switch.
The SPACIUM features a shield protecting electrical modules allowing access to the units trip switch and fuses. Command buttons are situated on the right-hand side.
- Protection index IP55 (resistant to water projections, compatible with a damp environment ).
- Protection of the command circuit (switch and timeclock) with live and neutral circuit breaker.
- Protection of transformer (if a projector is used).
- 230V - 12V transformer (if a projector is used) conform to norm EN61558 - 2 - 6.
- Protected primary circuit with live and neutral circuit breaker.
- 2 25A 12V outlets for the models featuring 2 projectors.
- 3 position switch (Stop, start, automatic) used for filtration.
- 3 position switch (Stop, start, automatic) used for filtration for slave option.
- 2 position switch (On and off) to command projector(s)).
- Earth terminal.
- The slave terminals are used for connecting the command system of automatic treatments (electrolysers, dosing pumps, etc...).
- The mounted trip switches are dual pole for single phase versions and three-pole for three-phased versions.
- For a three phase pump, order the model without trip switch and add the three-pole trip adapted to your pump (see table below).
The command box
Installation of the box :
The command box must be placed in an easy to reach area, that permits correct operation (C15-100 et 771,558), correctly aired, easy access with no obstacles placed in front of the box. The box should be placed between 1m and 1,80m above ground level. Height is limited to 1,30m, taking into account wheelchair access (C15-100 et 771,558). Prohibited in volumes 0,1 and 2. (C15-100 and 702,51). The box should be installed at a minimum distance of 3,50m from the pool and by preference, in the technical shelter.
Command details
1. Timeclock programming
2. Thermal magnetic circuit breaker
3. Projector and pump protection fuses
4. Command switch for filtration
5. Command switch for projectors
6. Contact terminal for eventual slave options
7. Terminal connection for the electrical box power supply 220V (or 380V)
8. Transformer for projector
9. Terminal connection for projectors + ELV protection fuse
Power cables
The cable sections must be dimensioned to support the amperage of the box. The cable length must not cause a voltage drop greater than 5% of the original power source generated (C15-100 section 525). Table 1 shows the values for a copper cable, depending on the dimension of its section, power source, maximum amperage and maximum length for the indicated amperage. The ELV (12V) of the pool : Table 2 shows values for a copper cable section, depending on the power of the transformer and the cable section. The guidelines concerning the ELV cable section, circuit breaker and trip switch dimensions are given in the guide UTE C15-559. In the case of voltage drop, the norm cannot be applied for residential pools as the lifespan of the material will be diminished.
Table indicating amperage to calibrate trip switches
Single-phase installation 230V
Capacity of filtration pump (kW / HP) Calibred trip switch Amperage
0,25 / 0,33 1,6 / 2,5 2,2 A
0,37 / 0,50 2,4 / 4,0 3,12 A
0,55 / 0,75 4 / 6,3 4,76 A
0,75 / 1 4 / 6,3 6,01 A
1,1 / 1,5 6 / 10 7,60 A
1,5 / 2 10 / 16 10,40 A
Three-phase installation 400V
Capacity of filtration pump (kW / HP) Calibred trip switch Amperage
0,25 / 0,33 1,0 / 1,6 0,9 A
0,37 / 0,50 1,0 / 1,6 1,2 A
0,55 / 0,75 1,6 / 2,5 1,60 A
0,75 / 1 1,6 / 2,5 2 A
1,1 / 1,5 2,5 / 4 2,60 A
1,5 / 2 2,5 / 4 3,50 A
2,2 / 3 4 / 6,3 5 A
3 / 4 6 / 10 6,60 A
Security volumes for pools
Security volumes for pools
Electrical installation for pools
Installation schema for electrical box
1. Electrical box 3. Projector
2. Filtration pump 4. Option : Booster pump, dosing pump etc.
In respect of electrical norms C15-100 the power supply of an electrical box for filtration purposes should be fitted with a 30mA differential switch.
The SPACIUM features a shield protecting electrical modules allowing access to the units trip switch and fuses. Command buttons are situated on the right-hand side.
- Protection index IP55 (resistant to water projections, compatible with a damp environment ).
- Protection of the command circuit (switch and timeclock) with live and neutral circuit breaker.
- Protection of transformer (if a projector is used).
- 230V - 12V transformer (if a projector is used) conform to norm EN61558 - 2 - 6.
- Protected primary circuit with live and neutral circuit breaker.
- 2 25A 12V outlets for the models featuring 2 projectors.
- 3 position switch (Stop, start, automatic) used for filtration.
- 3 position switch (Stop, start, automatic) used for filtration for slave option.
- 2 position switch (On and off) to command projector(s)).
- Earth terminal.
- The slave terminals are used for connecting the command system of automatic treatments (electrolysers, dosing pumps, etc...).
- The mounted trip switches are dual pole for single phase versions and three-pole for three-phased versions.
- For a three phase pump, order the model without trip switch and add the three-pole trip adapted to your pump (see table below).
The command box
Installation of the box :
The command box must be placed in an easy to reach area, that permits correct operation (C15-100 et 771,558), correctly aired, easy access with no obstacles placed in front of the box. The box should be placed between 1m and 1,80m above ground level. Height is limited to 1,30m, taking into account wheelchair access (C15-100 et 771,558). Prohibited in volumes 0,1 and 2. (C15-100 and 702,51). The box should be installed at a minimum distance of 3,50m from the pool and by preference, in the technical shelter.
Command details
1. Timeclock programming
2. Thermal magnetic circuit breaker
3. Projector and pump protection fuses
4. Command switch for filtration
5. Command switch for projectors
6. Contact terminal for eventual slave options
7. Terminal connection for the electrical box power supply 220V (or 380V)
8. Transformer for projector
9. Terminal connection for projectors + ELV protection fuse
Power cables
The cable sections must be dimensioned to support the amperage of the box. The cable length must not cause a voltage drop greater than 5% of the original power source generated (C15-100 section 525). Table 1 shows the values for a copper cable, depending on the dimension of its section, power source, maximum amperage and maximum length for the indicated amperage. The ELV (12V) of the pool : Table 2 shows values for a copper cable section, depending on the power of the transformer and the cable section. The guidelines concerning the ELV cable section, circuit breaker and trip switch dimensions are given in the guide UTE C15-559. In the case of voltage drop, the norm cannot be applied for residential pools as the lifespan of the material will be diminished.
Table indicating amperage to calibrate trip switches
Single-phase installation 230V
Capacity of filtration pump (kW / HP) Calibred trip switch Amperage
0,25 / 0,33 1,6 / 2,5 2,2 A
0,37 / 0,50 2,4 / 4,0 3,12 A
0,55 / 0,75 4 / 6,3 4,76 A
0,75 / 1 4 / 6,3 6,01 A
1,1 / 1,5 6 / 10 7,60 A
1,5 / 2 10 / 16 10,40 A
Three-phase installation 400V
Capacity of filtration pump (kW / HP) Calibred trip switch Amperage
0,25 / 0,33 1,0 / 1,6 0,9 A
0,37 / 0,50 1,0 / 1,6 1,2 A
0,55 / 0,75 1,6 / 2,5 1,60 A
0,75 / 1 1,6 / 2,5 2 A
1,1 / 1,5 2,5 / 4 2,60 A
1,5 / 2 2,5 / 4 3,50 A
2,2 / 3 4 / 6,3 5 A
3 / 4 6 / 10 6,60 A
Security volumes for pools
Security volumes for pools
Electrical installation for pools
Volume | ELV elements used | Appliance used |
0 | ELV | ELV |
1 | For small pools, a plug socket fitted with a differential circuit breaker superior to 30mA is admitted to more than 1,25m from the pool and lesser than 0,3m from ground level | ELV |
2 | ELV separating transformer (installed out of volumes 0, 1, 2). The power source should be protected with a differential greater than 30mA. | ELV separating transformer (installed out of volumes 0, 1, 2). The power source should be protected with a differential greater than 30mA. Class II lighting. |
Installation schema for electrical box
1. Electrical box 3. Projector
2. Filtration pump 4. Option : Booster pump, dosing pump etc.
Warranty
2 years
Photos non-contractual
Price incl. VAT
Price incl. VAT
Ask for a free quote spacium electrical box
Other product : SPACIUM electrical box
Starting from 464 eur Including VAT.
Please fill in this form carefully. Our commercial service will handle your request promptly.
UK freephone hotline
Monday Friday 9.00 18.00