Material and equipment for your technical shelter Electrical boxes for pools PANORAMA and MODULO electrical box
PANORAMA and MODULO electrical box
Recommended retail price 2024 starting from :
181 €
Our Price starting from :
269.90 € Including VAT
Ref. Abatik 009180
Ref. Provider PF10D104
PANORAMA PA20 4A/6A electrical box
Ref. Provider PF10D104
PANORAMA PA20 4A/6A electrical box
Timeclock for program and booster pump,
Slave depart,
Easy to use,
Many options.
Slave depart,
Easy to use,
Many options.
In stock
The use of an electrical box allows you to command and protect your filtration pump, power and protect your pool projectors. Depending on the chosen model, you can also command and protect other pool equipment, such as booster pumps, electrolysers, dosing pumps etc.
The PANORAMA and MODULO have a protection shield covering the electrical modules, allowing fast access to the trip switch and fuses.
- IP55 envelope (resistant to water projections, compatible with a damp environment ).
- Protection of the command circuit (switch and timeclock) with live and neutral circuit breaker.
- Protection of transformer (if a projector is used).
- 230V - 12V transformer (if a projector is used) conform to norm EN61558 - 2 - 6.
- Protected primary circuit with live and neutral circuit breaker.
- 3 position switch (Stop, start, automatic) used for filtration.
- 3 position switch (Stop, start, automatic) used for filtration for slave option.
- 2 position switch (On and off) to command projector(s)).
- Earth terminal.
- The slave terminals are used for connecting the command system of automatic treatments (electrolysers, dosing pumps, etc...).
- For a three phase pump, order the model without trip switch and add the three-pole trip adapted to your pump (see table below).
The PANORAMA and MODULO models are equipped with a mechanical timeclock that offers program segments of 30 mins.
A CCEI electrical box allows you to :
Optimise pool operation : Power supply, protection and control of electrical equipment : filtration pump, brush, projectors etc.
Peace of mind : Electrical boxes that are practical and conform to security norms.
CCEI guarantee : 35 years of experience, made in France, technical and commercial teams at your service.
User-friendly : Transparent access window offers better visibility to system operations (trip switch, timeclock), Cable entree integrated into casing of the box, ensuring personal and material security, protection of pump via trip switch, transformer conforms to norm NF EN61558.
The indicated references refer to a trip switch calabered up to 6,3 A (1 HP single-phase), excepting the models "without trip switch".
PANORAMA 20
PANORAMA PA 330/PA 370
PANORAMA PA 33PS/PA 37PS
The indicated refrences refer to use with a calabered trip switch up to 6,3A (1HP single-phase), excepting the models "without trip switch".
MODULO CP 20
MODULO CP 330/CP 370
MODULO CP 33PS/CP 37PS
The cable sections must be dimensioned to support the amperage of the box. The cable length must not cause a voltage drop greater than 5% of the original power source generated (C15-100 section 525).
Table 1 shows the values for a copper cable, depending on the dimension of its section, power source, maximum amperage and maximum length for the indicated amperage. The ELV (12V) of the pool : Table 2 shows values for a copper cable section, depending on the power of the transformer and the cable section. The guidelines concerning the ELV cable section, circuit breaker and trip switch dimensions are given in the guide UTE C15-559. In the case of voltage drop, the norm cannot be applied for residential pools as the lifespan of the material will be diminished.
230V single-phase installations
400V three-phase installation
Electrical box (1), Filtration pump (2), Projector (3), Slave option : Booster pump, dosing pump (4).
The PANORAMA and MODULO have a protection shield covering the electrical modules, allowing fast access to the trip switch and fuses.
- IP55 envelope (resistant to water projections, compatible with a damp environment ).
- Protection of the command circuit (switch and timeclock) with live and neutral circuit breaker.
- Protection of transformer (if a projector is used).
- 230V - 12V transformer (if a projector is used) conform to norm EN61558 - 2 - 6.
- Protected primary circuit with live and neutral circuit breaker.
- 3 position switch (Stop, start, automatic) used for filtration.
- 3 position switch (Stop, start, automatic) used for filtration for slave option.
- 2 position switch (On and off) to command projector(s)).
- Earth terminal.
- The slave terminals are used for connecting the command system of automatic treatments (electrolysers, dosing pumps, etc...).
- For a three phase pump, order the model without trip switch and add the three-pole trip adapted to your pump (see table below).
The PANORAMA and MODULO models are equipped with a mechanical timeclock that offers program segments of 30 mins.
A CCEI electrical box allows you to :
Optimise pool operation : Power supply, protection and control of electrical equipment : filtration pump, brush, projectors etc.
Peace of mind : Electrical boxes that are practical and conform to security norms.
CCEI guarantee : 35 years of experience, made in France, technical and commercial teams at your service.
User-friendly : Transparent access window offers better visibility to system operations (trip switch, timeclock), Cable entree integrated into casing of the box, ensuring personal and material security, protection of pump via trip switch, transformer conforms to norm NF EN61558.
PANORAMA range
The indicated references refer to a trip switch calabered up to 6,3 A (1 HP single-phase), excepting the models "without trip switch".
PANORAMA 20
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
PANORAMA PA20 without trip | Daily program timeclock | - | Yes | - | - | - |
PANORAMA PA20 | Daily program timeclock | - | Yes | - | - | - |
PANORAMA PA20 with differential | Daily program timeclock | - | Yes | - | - | Yes |
PANORAMA PA 330/PA 370
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
PANORAMA PA330 without trip | Daily program timeclock | - | - | 1 x 300W | - | - |
PANORAMA PA330 | Daily program timeclock | - | - | 1 x 300W | - | - |
PANORAMA PA330 with differential | Daily program timeclock | - | - | 1 x 300W | - | Yes |
PANORAMA PA370 without trip | Daily program timeclock | - | - | 2 x 300W | - | - |
PANORAMA PA370 | Daily program timeclock | - | - | 2 x 300W | - | - |
PANORAMA PA370 with differential | Daily program timeclock | - | - | 2 x 300W | - | Yes |
PANORAMA PA 33PS/PA 37PS
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
PANORAMA PA33PS without trip | Daily program timeclock | Yes | - | 1 x 300W | - | - |
PANORAMA PA33PS | Daily program timeclock | Yes | - | 1 x 300W | - | - |
PANORAMA PA37PS without trip | Daily program timeclock | Oui | - | 2 x 300W | - | - |
PANORAMA PA37PS | Daily program timeclock | Yes | - | 2 x 300W | - | - |
MODULO Range
The indicated refrences refer to use with a calabered trip switch up to 6,3A (1HP single-phase), excepting the models "without trip switch".
MODULO CP 20
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
MODULO CP 20 | Daily program timeclock | - | Yes | - | Yes | - |
MODULO CP 330/CP 370
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
MODULO CP 330 | Daily program timeclock | - | Yes | 1 x 300W | Yes | - |
MODULO CP 370 | Daily program timeclock | - | Yes | 2 x 300W | Yes | - |
MODULO CP 33PS/CP 37PS
Model | Filtration | Booster pump power supply | Socket supply 230 V slave filtration | Projector power supply | Slave Filtration depart | 30mA differential switch |
MODULO CP 33PS | Daily program timeclock | Yes | Yes | 1 x 300W | Yes | - |
MODULO CP 37PS | Daily program timeclock | Yes | Yes | 2 x 300W | Yes | - |
Cable sections
The cable sections must be dimensioned to support the amperage of the box. The cable length must not cause a voltage drop greater than 5% of the original power source generated (C15-100 section 525).
Table 1 shows the values for a copper cable, depending on the dimension of its section, power source, maximum amperage and maximum length for the indicated amperage. The ELV (12V) of the pool : Table 2 shows values for a copper cable section, depending on the power of the transformer and the cable section. The guidelines concerning the ELV cable section, circuit breaker and trip switch dimensions are given in the guide UTE C15-559. In the case of voltage drop, the norm cannot be applied for residential pools as the lifespan of the material will be diminished.
Table indicating amperage to caliber trip switches
230V single-phase installations
Filtration pump capacity (kW / HP) | Caliber of trip switch | Amperage |
0,25 / 0,33 | 1,6 / 2,5 | 2,2 A |
0,37 / 0,50 | 2,4 / 4,0 | 3,12 A |
0,55 / 0,75 | 4 / 6,3 | 4,76 A |
0,75 / 1 | 4 / 6,3 | 6,01 A |
1,1 / 1,5 | 6 / 10 | 7,60 A |
1,5 / 2 | 10 / 16 | 10,40 A |
400V three-phase installation
Filtration pump capacity (kW / HP) | Caliber of trip switch | Amperage |
0,25 / 0,33 | 1,0 / 1,6 | 0,9 A |
0,37 / 0,50 | 1,0 / 1,6 | 1,2 A |
0,55 / 0,75 | 1,6 / 2,5 | 1,60 A |
0,75 / 1 | 1,6 / 2,5 | 2 A |
1,1 / 1,5 | 2,5 / 4 | 2,60 A |
1,5 / 2 | 2,5 / 4 | 3,50 A |
2,2 / 3 | 4 / 6,3 | 5 A |
3 / 4 | 6 / 10 | 6,60 A |
Electrical installation conditions
Volume | ELV elements used | Appliance used |
0 | ELV | ELV |
1 | For small pools, a plug socket fitted with a differential circuit breaker superior to 30mA is admitted to more than 1,25m from the pool and lesser than 0,3m from ground level | ELV |
2 | ELV separating transformer (installed out of volumes 0, 1, 2). The power source should be protected with a differential greater than 30mA. | ELV separating transformer (installed out of volumes 0, 1, 2). The power source should be protected with a differential greater than 30mA. Class II lighting. |
Installation schema for electrical box
Electrical box (1), Filtration pump (2), Projector (3), Slave option : Booster pump, dosing pump (4).
Warranty
2 years
Photos non-contractual
Price incl. VAT
Price incl. VAT
Ask for a free quote panorama and modulo electrical box
Other product : PANORAMA and MODULO electrical box
Starting from 269.90 eur Including VAT.
Please fill in this form carefully. Our commercial service will handle your request promptly.
UK freephone hotline
Monday Friday 9.00 18.00
Spare parts order
You are looking for a spare part for «PANORAMA and MODULO electrical box» ?
Please click the button below. Our commercial service will handle your request promptly.