>> Hammam equipment and material Hammam lighting and accessories Teddington LS REG2 multifunctional programmer for hammam

Teddington LS REG2 multifunctional programmer for hammam

Teddington LS REG2 programmer for hammam
Recommended retail price 2024 starting from :
438 €
Our Price starting from :
438 € Including VAT
Ref. Abatik 011418
Ref. Provider LS-REG-2
Teddington LS REG2 multifunctional programmer for hammam
Manages regulation of temperature,
Program timeclock
Ventilation and lighting control
In stock
Teddington LS REG2 multifunctional programmer for hammam
Ref. Abatik 011418 Ref. Provider LS-REG-2
EUR 438
438 €
Order Free quote
Teddington wellness digital distance control panel LS-SKW22
Ref. Abatik 011419 Ref. Provider SKW22
EUR 161
161 €
Order Free quote

Teddington LS REG2 multifunctional programmer


The multifunctional programmer is the essential complement for TEDDINGTON hammams.
Easy to use and regulate, offering automated operation of your hammam.

- Provides or ceases steam production in relation to the desired temperature.
- Timeclock programming for automatic start and stop of steam production.
- Preheat timer operational during the selected time.
- ECO mode to maintain the hammam at an ambient temperature when not in use.
- Ventilation control to dry hammam during the night following use.
- Hammam lighting control - operational during the day or only when hammam is in use.
- Service lighting management to facilitate maintenance and cleaning.

Precision of temperature regulation +/- 1°C.
Supplied with 3m connected cable and sensor.
Teddington LS REG2 multifonctional programmer for hammam


Characteristics


Index of protection
IP 65
Numbers displayed
3
Precision of data
1°C
Dry contact output
3 Amps - NO
Power supply
24V (L+N)
Depth x height x width
59 x 32 x 74mm
Patress cut
29 x 71mm

Operational limits


Ambient temperature
-5 to +55°C
Humidity on front panel
10 to 100%
Temperature (sensor)
-50 to +100°C

Distance control



Distance management Teddington LS REG2

Display panel and distance management for the LS REG2

Notes from users manual


Main features:
Hammam temperature control and adjustment.
Hammam start and stop
Programmation to correspond with opening and closing times of hammam
Timer for hammam programming
Time clock for hammam preheat
Use of time clock with regular temperature
Hammam lighting management
Hammam ventilation management

Temperature regulation of hammam:
The Wellness regulator uses two reference points: reference point 1 « preheat» and reference point 2 « user temperature ».
This limits energy consumption when the hammam is unoccupied, preheating efficiently and ensuring a fast temperature rise.
When the hammam is open to the public, steam production always commences at preheat temperature.

Programming of hammam opening times:
The Wellness programmer uses a real-time internal time clock.
Steam production can, therefore, start or stop depending on the opening times of the establishment.

Timer use with a steam generator:
This mode of use is recommended for both public and residential use.

By using this method, the steam generator is always available to be used at the reference temperature during the predefined time.

Use of steam generator using time clock with automatic start, preheat at 30°C and timer use at 42°C:
This mode is recommended for use in public hammams, hotels, spas, beauty salons...
- When the establishment opens, the steam generator will start at preheat temperature.
- By pressing the appropriate button, user reference temperature begins during the selected duration of time.
- Following temporisation, the regulator will go to preheat.
- Press the button « ESC » at the end of the session to go to the normal reference temperature.
- When the establishment closes, the steam generator stops.

An example of required settings:
Preheat: 30°C
Normal temperature: 42°C
Opening time: 11:30
Closing time: 23:00
Temporisation time: 60 minutes
Indicating the steam generator will commence operation at 11h30 to preheat the hammam at 30 °C.

Use of steam generator using time clock with an automatic start at normal reference temperature:
This mode is recommended for public hammams.
- When the establishment opens, the steam generator will start at preheat temperature.
- If required, press « ESC » before the end of the session to go to reduced temperature.
- When the establishment closes, the steam generator stops.

An example of required settings:
- Preheat: 42°C
- Normal temperature: 42°C
- Opening time of establishment: 11:30
- Closing time of establishment: 23:00
- Operational temporisation 999 minutes
The steam generator will automatically start at 11h30 to preheat the hammam at 42 °C during the whole day.

Hammam lighting
You have the choice of two lighting systems:
"Active" lighting, operational during hammam opening hours at normal reference temperature: recommended for residential hammams.
The steam generator manages lighting during hammam operation at the normal referent temperature.
Service lighting: Provides lighting adapted to maintenance and cleaning.

Ventilation :
Dry the hammam during night hours or after use.
The ventilator provides three operational modes for extracting air from the hammam:
1 – The ventilator operates when the hammam is closed.
This mode is strongly recommended for public hammams and hotels.
2 – The ventilator operates during several hours after hammam use. This mode is recommended for residential hammams.
3 – The ventilator operates in a sequenced manner and during closing hours.
Recommended for hammams which are very isolated or poorly ventilated, forcing steam production.

Warranty

2 years

Photos non-contractual
Price incl. VAT

Ask for a free quote teddington ls reg2 multifunctional programmer for hammam

Other product : Teddington LS REG2 multifunctional programmer for hammam
Starting from 438 eur Including VAT.

Please fill in this form carefully. Our commercial service will handle your request promptly.


UK freephone hotline

Monday Friday 9.00 18.00

contact tel


 

Spare parts order

You are looking for a spare part for «Teddington LS REG2 multifunctional programmer for hammam » ?

Please click the button below. Our commercial service will handle your request promptly.